Combined Cycle CHP Power Plant 12.5 MWe + 1.6 MW Chilled Water

This combined cycle CHP (trigeneration) power plant provides a total electrical capacity of 12.5 MWe along with 1.6 MW of chilled water for process cooling. The plant configuration comprises a dual-fuel gas turbine, a back-pressure steam turbine, a heat recovery steam generator (HRSG), and double-effect absorption chiller, delivering efficient cogeneration and trigeneration performance.

SKU: 10932026

Manufacturer
Solar Turbines and Siemens
Manufacturer's type
Solar Mars 100 and SST 060 Back Pressure
Made in year
2007
Capacity
10MW+2.5MW Chiller 1.6 MW
Application
Base Load Electric Power and Chilled Water Production
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine
  • Combined cycle CHP (trigeneration) power plant with Solar Mars 100 Dual Fuel Turbine

Combined Cycle CHP Power Plant 12.5 MWe + 2.8 MW Chilled Water

This combined cycle CHP plant consists of one Dual Fuel Solar Turbine Mars 100 with 40 bar steam boiler, Siemens SST 060 Back Pressure Steam Turbine and one Double Acting LS Absorption Chiller with electrical, mechanical and control auxiliaries. Plant is maintained according to manufacturer’s instruction. Gas turbine engine was changed to Solar refurbished unit in June 2023 and it has accumulated only about 16000 hours since that. Both the gas turbine and the steam turbine were last overhauled by OEM service in mid-2025 and thus equipment is in good operational condition.

This combined cycle CHP (trigeneration) plant delivers 10 MWe of primary electrical output from a Solar Turbines Mars 100 dual-fuel gas turbine, with an additional 2.5 MWe from a Siemens SST 060 back-pressure steam turbine and 1.6 MWth of chilled water from two LS double-effect absorption chillers. The total combined electrical capacity is 12.5 MWe.

The turbine exhaust feeds a Descon water-tube HRSG with supplementary duct burner, producing up to 30 tons/h of superheated steam at 42 bar and 255°C. Steam drives the Siemens back-pressure turbine (year 2012), with exhaust steam at 7–9 bar feeding the absorption chillers for process cooling. The plant includes a fuel gas booster compression system, a nearly new GEA diesel fuel purifiers (year 2023), and a comprehensive inventory of original spare parts for all major components.

Technical Characteristics

  • Electrical capacity                12,5 MWe / 11 kV / 50 Hz
  • Cooling capacity                   Approx 1.6 MWth (12°C inlet / 7°C outlet)
  • Plant commissioning year    2007
  • Fuel                                      GAS / LFO
  • Gas Turbine                         Solar Mars 100 (10 MWe)
  • Reduction Gearbox              Renk MAAK GPF3-28
  • Generator                             Leroy Somer LSA 58 (12,500 kVA)
  • Fuel Gas Compressor          Enerproject EGS-S-400/400
  • Diesel Purifier                     2 x Westfalia OSE 20-01-037
  • Heat Recovery Boiler         LC Cable 30 TPH, water tube, 42 bar / 491°C
  • Steam Turbine                     Siemens SST 060 Back-pressure (2.5 MWe)
  • Absorption Chillers            Double Acting LSH-S050S 
  • Control PLC                       Siemens S7-300

Watch a video of running plant