Diesel Generator Power Plant 106 MW with Wartsila 7x18V46 HFO

Complete equipment packaged for 106 MW HFO Diesel Power Plant with seven units of Wartsila 18V46 HFO diesel generators and all auxiliaries. Professionally dismantled in 2017 - ready for immediate shipping!

SKU: 4832017

Manufacturer
Wartsila
Manufacturer's type
7 x 18V46 HFO
Made in year
2002
Capacity
106 MW
Application
HFO Diesel Generators
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7 x 18V46 HFO
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING
  • Diesel Generator Wartsila 7x18V46 AFTER DISMANTLING

Diesel Generator Power Plant 106 MW with Wartsila 7x18V46 HFO  

This 106 MW power plant (site condition) was delivered by Wartsila in year 2002, operation started in 2003 and it has 7 x 18V46 diesel engines running on heavy fuel oil (HFO) at 500 rpm coupled with ABB made brushless synchronous 11 kV / 50 Hz alternators. I has been in operated under PPA and engines have been operated around 50 000 / 70 000 hours in base load power production. This power plant is designed and build by Wartsila utilizing their highly standardized functional module delivery. Operation and maintenance works were carried out strictly in accordance with Wartsila manuals. The plant was professionally dismantled in 2017. During the operation no any unexpected breakdowns has happened.  

Main plant characteristics at current site conditions:  

Power output from alternators                        106 MW at 11 kV / 50 Hz

Engines                                                           7 x 18V46 - 500 rpm

Alternators                                                      ABB AMG 1600 SS12 DSEB self-cooled, brushless, synchronous

Power factor                                                   0.8

Efficiency                                                       0.97 (at rated output, 50 Hz and power factor 0.8)

Voltage                                                           11 000 V, with adjustment range +5 - 10%

Frequency                                                       50 Hz +/-5%

Fuel consumption gross                                 8290 - 8330 kJ/kWh (43.4 to 43.2 % efficiency)

Lube oil consumption                                    0.7 g/kWh 

Cooling system                                              Closed loop radiator cooling

Fuel Oil                                                          HFO viscosity max 380 cSt / 50 °C