Gas Power Plant 41.8 MW with Wartsila 6 x 16V34SG generators, year 2008

Complete running power plant with 6 units of Wartsila 16V34SG spark ignited natural gas engine driven generators. The equipment was delivered and commissioned by Wartsila in year 2008 and today the units have approx 25 000 operating hours. The equipment is in very good operational condition but the engines need a 24 000 hour overhaul.

SKU: 3722016

Manufacturer
Wartsila
Manufacturer's type
6 x 16V34SG Simble Cycle
Made in year
2008
Capacity
41.8 MW
Application
Base Load Power Production
Installed power
41 820 kW at 31.5 kV, 50 Hz
Engines
6 x W16V34SG, running at 750 rpm
Alternators
6 x AKV 8712 kVA, 11 kV, 50 Hz, p.f. 0.8
Heat rate - original from alternators
8140 kJ/kWhe (44.2 %)
Plant own power consumption
836 kW
Total operating hours
approx 25000 /unit
Engine cooling system
Closed loop radiators
Status
Installed, in peak load operation
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators
  • Gas power plant with 6 x Wartsila 16V34SG generators

Natural Gas Power Plant with 6 x Wartsila 16V34SG generators 

Generators are installed on common base frame with the engines and common base frame is isolated from the foundation by flexible mounting with steel springs. Most of the auxiliaries are in the factory built in large new type modules which enable easy relocation of the equipment. 

The engines are of the four stroke, lean burn, pre chamber, spark ignited, port injected, trunk piston, turbocharged and intercooled design. The engine automation is a complete embedded management system, integrated with an engine control system for electricity controlled fuel injection. The control system is distributed bus based system where monitoring and control function is placed close to measuring and control point. This leads to less wiring and improved performance. The engines are designed for continuous operation in gas mode in island mode at any load between 40 -100% of nominal power